Standard Injectors
SUITABLE FOR STEAM PRESSURES UP TO 250 PSI WITH WATER PRESSURE SUPPLY FOR SUCTION LIFT APPLICATIONS WITH STEAM PRESSURE FROM 25 TO 140 PSI
Metcalfe Standard Injectors are available in two body styles and 8 sizes with screwed connections from ⅜" to 2½" pipe size. They are designed to meet the requirements of most applications and will operate satisfactorily within the following range of operating conditions.
Water Pressure Supply Applications
Metcalfe Standard Injectors are available in two body styles and 8 sizes with screwed connections from ⅜" to 2½" pipe size. They are designed to meet the requirements of most applications and will operate satisfactorily within the following range of operating conditions.
Suction Lift Applications
- Start Low: 25 PSI steam pressure with 3ft lift and 74°F water
- Work High: up to 140 PSI steam pressure with 3ft lift and 74°F water
- Lift Water: 20ft at 60 to 80 PSI steam pressure with 74°F water
Maximum Temperature of Suction Water with 3ft Lift and at Steam Pressures as Follows:
- 120°C at 60 to 80 PSI
- 115°C at 100 PSI
- 105°C at 120 PSI
- 90°C at 140 PSI
Size No. | Boiler Horse Power Rating | Pipe Size Conn. (IN) | Shipping Weight Boxed (LB) |
---|---|---|---|
00-21 | 12 | ⅜" | 2½ |
AA-21 | 25 | ½" | 3½ |
BB-21 | 50 | ¾" | 5½ |
CC-21 | 85 | 1" | 8 |